Other information:
Diagnosis Procedure
Back door auto closure function does not operate when back door opening and closing operations are performed.CHECK DTC WITH AUTOMATIC BACK DOOR CONTROL MODULE
Check that DTC is not detected with automatic back door control module.
Is the inspection result normal?
YES>>
GO TO 2...
Trouble Diagnosis For Unusual Pressure
Diagnose using a manifold gauge whenever system’s high and/or low side pressure(s) is/are unusual. The marker above the gauge scale in the following tables indicates the standard (usual) pressure range.
Symptom Table
Gauge indication Refrigerant cycle Probable cause Corrective action
Both high and low pressure sides are too high...