Other information:
Reference Value
TERMINAL LAYOUTPHYSICAL VALUES
Terminal No.
(Wire color) Description Condition
Voltage
(Approx.)
+ - Signal name Input/Output
1
(R)
Ground
Battery
Input
Supplies power to sunshade motor.
Battery voltage
5
(B)
Ground
Ground
—
—
0 V
9
(W)
Ground
LIN communication
Input/Output
Provides communication link between sunshade motor assembly and moonroof motor assembly...
Description
MAINTENANCE OF OIL LEVELThe compressor oil is circulating in the system together with the refrigerant. It is necessary to fill compressor with oil when replacing A/C system parts or when a large amount of refrigerant leaks are detected. It is important to always maintain oil level within the specified level or the following conditions may occur:
Insufficient oil amount: Stuck compressor
Excessive oil amount: Insufficient cooling (caused by insufficient heat exchange)
Oil Type