On Board Diagnosis Function
COMBINATION METER SELF-DIAGNOSIS MODEThe following meter functions can be checked during Combination Meter Self-Diagnosis Mode:
Pointer sweep of speedometer, tachometer and gauges
Illumination of all LCD segments and color patterns for meter displays
Illumination of all lamps/LEDs that are controlled by the combination meter (regardless of switch status)
STARTING COMBINATION METER SELF-DIAGNOSIS MODENOTE:
Check combination meter power supply and ground circuits if self-diagnosis mode does not start...
Other information:
Capacity
(US qt, Imp qt) Engine coolant capacity*
8.7 (9-1/4, 7-5/8)
*: Includes 0.8L with coolant reservoir tank at MAX level.
Thermostat
Valve opening temperature
82°C (180°F)
Full-open lift amount
8.6 mm / 95°C (0.339 in / 203°F)
Valve closing temperature
77°C (171°F)
Radiator
Unit: kPa (kg/cm2, psi) Cap relief pressure
Standard
118 ± 9...
Diagnosis Procedure
CHECK EACH DOOR MOTOR POWER SUPPLY
Ignition switch ON.
Check voltage between intake door motor harness connector and ground.
+ −
Voltage
(Approx.)
Intake door motor
Connector Terminal
M153
1
Ground
Battery voltage
Is the inspection result normal?
YES>>