Nissan Murano: Meter, Warning Lamp & Indicator :: Symptom Diagnosis / The Ambient Temperature Display Is Incorrect
Diagnosis Procedure
-
The displayed outside air temperature is higher than the actual temperature.
-
The displayed outside air temperature is lower than the actual temperature.
-
Outside air temperature is not indicated.
CHECK AMBIENT SENSOR SIGNAL CIRCUIT
Check the ambient sensor signal circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace harness or connector.
CHECK AMBIENT SENSOR
Check the ambient sensor. Refer to Component Inspection.
Is the inspection result normal?
YES>>
Replace combination meter. Refer to Removal and Installation.
NO>>
Replace ambient sensor. Refer to Removal and Installation.
Diagnosis Procedure
One or more of the steering switches to control the information display are inoperative.CHECK STEERING SWITCH CIRCUIT
Check steering switch circuit...
Other information:
Description
Performing the following procedure can automatically activate recommunication of ECM and BCM, but only when the ECM is replaced with a new one*.*: New one means an ECM that has never been energized on-board.(In this step, initialization procedure by CONSULT is not necessary)CAUTION:
When replacing the ECM, a new ECM must be used...
DTC Description
DTC DETECTION LOGICThe heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst 1 causes the longer switching time. To judge the malfunctions of heated oxygen sensor 2, ECM monitors whether the switching response of the sensor's voltage is faster than specified during various driving conditions such as fuel cut...