DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | |
| P0712 |
FLUID TEMP SENSOR A (Transmission Fluid Temperature Sensor A Circuit Low) |
Diagnosis condition | TCM power supply voltage: More than 11 V |
| Signal | CVT fluid temperature sensor signal | ||
| Threshold | Fluid temperature sensor detection voltage: 0.15 V or less | ||
| Diagnosis delay time | Maintained for 5 seconds | ||
POSSIBLE CAUSE
Harness or connector (CVT fluid temperature sensor circuit is shorted to ground)
CVT fluid temperature sensor
FAIL-SAFE
Engine coolant temperature when engine start: Temp. ≥ 10°C (50°F)
Start is slow
Acceleration is slow
Engine coolant temperature when engine start: −35°C (−31°F) ≤ Temp. < 10°C (50°F)
Selector shock is large
Start is slow
Acceleration is slow
Engine coolant temperature when engine start: Temp. <−35°C (−31°F)
Selector shock is large
Start is slow
Acceleration is slow
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
Start the engine and wait for 10 seconds or more.
Check the first trip DTC.
Is “P0712” detected?
YES>>Go to Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
CHECK CIRCUIT BETWEEN TCM AND CVT UNIT
Turn ignition switch OFF.
Disconnect TCM connector and CVT unit connector.
Check continuity between TCM harness connector terminal and ground.
| TCM | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| F25 | 12 | Ground | Not existed |
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace malfunctioning part.
CHECK TERMINAL CORD ASSEMBLY
Check continuity between CVT unit connector terminal and ground
| CVT unit | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| F210 | 12 | Ground | Not existed |
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace terminal cord assembly. Refer to Removal and Installation.
CHECK CVT FLUID TEMPERATURE SENSOR
Check resistance between CVT unit connector terminals.
| CVT unit | Condition |
Resistance (Approx.) | |
|---|---|---|---|
| Connector | Terminal | ||
| F210 | 12 – 18 | CVT fluid temperature: 20°C (68°F) | 6.5 kΩ |
| CVT fluid temperature: 50°C (122°F) | 2.2 kΩ | ||
| CVT fluid temperature: 80°C (176°F) | 0.87 kΩ | ||
Is the inspection result normal?
YES>>Check intermittent incident. Refer to Intermittent Incident.
NO>>Replace terminal cord assembly. Refer to Removal and Installation.