CHECK FUNCTION
CONSULT
Select “HALF LATCH SW” in “Data Monitor” mode of “AUTO BACK DOOR”.
Check that the function operates normally according to the following conditions:
| Monitor Item | Condition | Status | |
|---|---|---|---|
| HALF LATCH SW | Back door | Open/fully closed | OFF |
| Half latch | ON | ||
Is the inspection result normal?
YES>>Half latch switch is OK.
NO>>Refer to Diagnosis Procedure.
CHECK HALF LATCH SWITCH INPUT SIGNAL
Ignition switch OFF.
Disconnect back door lock assembly connector.
Check voltage between back door lock assembly harness connector and ground.
| (–) | (–) |
Voltage (Approx.) | |
|---|---|---|---|
| Back door lock assembly | |||
| Connector | Terminal | ||
| D557 | 6 | Ground | Battery voltage |
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK HALF LATCH SWITCH CIRCUIT
Disconnect automatic back door control module connector.
Check continuity between automatic back door control module harness connector and back door lock assembly harness connector.
| Automatic back door control module | Back door lock assembly | Continuity | ||
|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |
| B55 | 3 | D557 | 6 | Yes |
Check continuity between automatic back door control module harness connector and ground.
| Automatic back door control module | Ground | Continuity | |
| Connector | Terminal | ||
| B55 | 3 | No | |
Is the inspection result normal?
YES>>Replace automatic back door control module. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK HALF LATCH SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
| Back door lock assembly | Ground | Continuity | |
| Connector | Terminal | ||
| D557 | 8 | No | |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK HALF LATCH SWITCH
Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace back door lock assembly. Refer to Removal and Installation.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
>>
Inspection End.
CHECK HALF LATCH SWITCH
Ignition switch OFF.
Disconnect back door lock assembly connector.
Check continuity between back door lock assembly terminals.
| Back door lock assembly | Condition | Continuity | ||
| Terminal | ||||
| 6 | 8 | Back door | Open | Yes |
| Fully closed/Half latch | No | |||
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace back door lock assembly. Refer to Removal and Installation.
Key Warning Lamp
Touch Sensor. Rh
The gauge indicates the approximate fuel level in the tank.
The gauge may move slightly during braking, turning, acceleration, or going up or down hills.
The gauge needle returns to 0 (Empty) after the ignition switch is placed in the OFF position.