Nissan Murano: Basic Inspection / Clutch Point Learning
Description
TCM memorizes a clutch point (engagement timing), and this enables accurate control. For work procedure, refer to Work Procedure.
Work Procedure
CLUTCH POINT LEARNING
With CONSULT
-
Start the engine.
-
Select “Work Support” in “TRANSMISSION”.
-
Select “FWD CLUTCH POINT LEARNING”.
-
Perform learning according to the CONSULT display.
CAUTION:
After the completion in D position, perform in R position.
>>
WORK END
Description
When replacing TCM and transaxle assembly simultaneously, perform the following work. For work procedure, refer to Work Procedure.NOTE:
The CD provided with the new transaxle assembly contains important calibration data that must be installed with CONSULT after installation of the new transaxle assembly...
Work Procedure
NOTE:
If Clutch Point Learning is also required, always perform Clutch Point Learning before Select Learning.
Perform Select Learning with CVT fluid temperature below 50°C (122°F) and again with fluid temperature above 50°C (122°F)...
Other information:
Description
Main power window and door lock/unlock switch, power window and door lock/unlock switch RH and BCM transmit and receive the signal by power window serial link.The signal mentioned below is transmitted from BCM to main power window and door lock/unlock switch and power window and door lock/unlock switch RH
Keyless power window down signal
The signal mentioned below is transmitted from main power window and door lock/unlock switch to power window and door lock/unlock switch RH
Front door window RH operation signal
Retained power operation signal
Power window lock switch signal
Component Function Check
CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
CONSULT
Select “CDL LOCK SW ” or “CDL UNLOCK SW” in “Data Monitor” mode of “BCM(DOOR LOCK)”...
Diagnosis Procedure
CHECK CONNECTOR
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the ECM for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES>>
GO TO 2...