DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) | DTC detection condition | ||
|---|---|---|---|---|
| P0037 |
HO2S2 HTR (B1) (HO2S heater control circuit low bank 1 sensor 2) |
A | Diagnosis condition | — |
| Signal (terminal) | Voltage signal transmitted from heated oxygen sensor 2 heater to ECM | |||
| Threshold | An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater | |||
| Diagnosis delay time | — | |||
| B | Diagnosis condition | — | ||
| Signal (terminal) | — | |||
| Threshold | ECM detects the heated oxygen sensor 2 heater circuit is short to ground. | |||
| Diagnosis delay time | — | |||
| P0038 |
HO2S2 HTR (B1) (HO2S heater control circuit high bank 1 sensor 2) |
Diagnosis condition | — | |
| Signal (terminal) | Voltage signal transmitted from heated oxygen sensor 2 heater to ECM | |||
| Threshold | An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater | |||
| Diagnosis delay time | — | |||
| P0057 |
HO2S2 HTR (B2) (HO2S heater control circuit low bank 2 sensor 2) |
A | Diagnosis condition | — |
| Signal (terminal) | Voltage signal transmitted from heated oxygen sensor 2 heater to ECM | |||
| Threshold | An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater | |||
| Diagnosis delay time | — | |||
| B | Diagnosis condition | — | ||
| Signal (terminal) | — | |||
| Threshold | ECM detects the heated oxygen sensor 2 heater circuit is short to ground. | |||
| Diagnosis delay time | — | |||
| P0058 |
HO2S2 HTR (B2) (HO2S heater control circuit high bank 2 sensor 2) |
Diagnosis condition | — | |
| Signal (terminal) | Voltage signal transmitted from heated oxygen sensor 2 heater to ECM | |||
| Threshold | An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater | |||
| Diagnosis delay time | — | |||
POSSIBLE CAUSE
P0037
Harness or connectors (The heated oxygen sensor 2 heater circuit is open or shorted.)
Heated oxygen sensor 2 heater
P0038
Harness or connectors (The heated oxygen sensor 2 heater circuit is shorted.)
Heated oxygen sensor 2 heater
P0057
Harness or connectors (The heated oxygen sensor 2 heater circuit is open or shorted.)
Heated oxygen sensor 2 heater
P0058
Harness or connectors (The heated oxygen sensor 2 heater circuit is shorted.)
Heated oxygen sensor 2 heater
FAIL-SAFE
Not applicable
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5 V and 16 V at idle.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
Start engine and warm it up to the normal operating temperature.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
Let engine idle for 1 minute.
Check 1st trip DTC.
Is 1st tip DTC detected?
YES>>Proceed to Diagnosis Procedure.
NO>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO>>Confirmation after repair: INSPECTION END
CHECK HO2S2 POWER SUPPLY
Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
Turn ignition switch ON.
Check the voltage between HO2S2 harness connector and ground.
| DTC | HO2S2 | Ground | Voltage | ||
|---|---|---|---|---|---|
| Bank | Connector | Terminal | |||
| P0037, P0038 | 1 | F62 | 1 | Ground | Battery voltage |
| P0057, P0058 | 2 | F54 | 1 | ||
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK HO2S2 SENSOR 1 POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect IPDM E/R harness connector.
Check the continuity between HO2S2 harness connector and IPDM E/R harness connector.
| DTC | HO2S2 | IPDM E/R | Continuity | |||
|---|---|---|---|---|---|---|
| Bank | Connector | Terminal | Connector | Terminal | ||
| P0037, P0038 | 1 | F62 | 1 | F19 | 52 | Existed |
| P0057, P0058 | 2 | F54 | 1 | 53 | ||
Is the inspection result normal?
YES>>Perform the trouble diagnosis for power supply circuit.
NO>>Repair or replace error-detected parts.
CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between HO2S2 harness connector and ECM harness connector.
| DTC | HO2S2 | ECM | Continuity | |||
|---|---|---|---|---|---|---|
| Bank | Connector | Terminal | Connector | Terminal | ||
| P0037, P0038 | 1 | F62 | 2 | F78 | 7 | Existed |
| P0057, P0058 | 2 | F54 | 2 | 47 | ||
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair open circuit, short to ground or short to power in harness or connectors.
CHECK HEATED OXYGEN SENSOR 2 HEATER
Check heated oxygen sensor 2 heater. Refer to Component Inspection.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2), Removal and Installation (bank 1).
CHECK HEATED OXYGEN SENSOR 2 HEATER
Turn ignition switch OFF.
Disconnect heated oxygen sensor 2 harness connector.
Check resistance between HO2S2 terminals as per the following.
| + | − | Resistance |
|---|---|---|
| Heated oxygen sensor 2 | ||
| Terminal | ||
| 1 | 2 | 3.0 Ω [at 25°C (77°F)] |
| 3 | 1 |
∞Ω (Continuity should not exist) |
| 2 | ||
| 4 | ||
| 4 | 1 | |
| 2 | ||
| 3 | ||
Is the inspection result normal?
YES>>INSPECTION END
NO>>Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2), Removal and Installation (bank 1).
P0031 A/f Sensor 1 Heater
P0053 A/f Sensor 1 Heater