Located in IPDM E/R, it runs the starter motor. The starter relay is turned ON by the BCM when ignition switch is in START position. IPDM E/R transmits the starter relay ON signal to BCM via CAN communication.
DTC DETECTION LOGIC
NOTE:
If DTC B210E is displayed with DTC U1000, first perform the trouble diagnosis for DTC U1000. Refer to DTC Description.
If DTC B210E is displayed with DTC U1010, first perform the trouble diagnosis for DTC U1010. Refer to DTC Description.
| DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC Detection Condition | |
|---|---|---|---|
| B210E |
STARTER RLY OFF CIRC (Starter relay off circuit) |
Diagnosis condition | When ignition switch ON. |
| Signal (terminal) | — | ||
| Threshold |
IPDM E/R detects that the relay is stuck at ON position even if the following conditions are met for about 1 second:
|
||
| Diagnosis delay time | — | ||
POSSIBLE CAUSE
IPDM E/R
Harness or connector
FAIL-SAFE
—
PERFORM DTC CONFIRMATION PROCEDURE
CONSULT
Ignition switch ON under the following conditions and wait for at least 1 second:
CVT selector lever is in the P (Park) or N (Neutral) position.
Do not depress the brake pedal.
Select “Self Diagnostic Result” mode of “IPDM E/R”.
Check DTC.
Is DTC detected?
YES>>Refer to Diagnosis Procedure.
NO>>Inspection End.
CHECK STARTER RELAY OUTPUT SIGNAL/CVT MODELS
Ignition switch OFF.
Disconnect BCM harness connector.
Check voltage between BCM harness connector ground.
| (+) | (–) | Condition |
Voltage (Approx.) | |||
|---|---|---|---|---|---|---|
| BCM | ||||||
| Connector | Terminal | Ignition switch | Brake pedal | CVT selector lever | ||
| M19 | 62 | Ground | ON | Depressed | P (Park) or N (Neutral) | Battery voltage |
| Other than above | 0 V | |||||
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>GO TO 2.
CHECK STARTER RELAY OUTPUT SIGNAL CIRCUIT
Disconnect IPDM E/R harness connector.
Check continuity between IPDM E/R harness connector and BCM harness connector.
| IPDM E/R | BCM | Continuity | ||
|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |
| E119 | 33 | M19 | 62 | Yes |
Check continuity between BCM harness connector and ground.
| IPDM E/R | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| E119 | 33 | Ground | No |
Is the inspection result normal?
YES>>Replace IPDM E/R. Refer to Removal and Installation.
NO>>Repair harness connector.